Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.1.2.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Basements used primarily as storage garages, where the floor and roof assemblies above the basements and the exterior walls of the basements above the adjoining ground level are constructed as fire separations of masonry or concrete having a fire-resistance rating of not less than 2 h.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as exempted in Sentence 3.2.1.2.(2), which applies to openings in exterior walls of basements where certain conditions are met.
Top of Page
Intent
Intent 1: 
To allow a basement storage garage to be considered as a separate building from the portion above if certain measures are taken.
These measures are to limit the probability of the spread of fire from the garage to the upper portions of the building during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to harm to persons in the upper portions of the building, including emergency responders.