Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.1.4.(1) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of
floor assemblies immediately above basements, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to a crawl space required to be
considered as a basement, as stated in Sentence 3.2.2.9.(1).
Exceptions:
except as exempted in Sentences 3.2.2.42.(3), 3.2.2.43.(3), 3.2.2.44.(3), 3.2.2.45.(3), 3.2.2.46.(3), 3.2.2.47.(3) and 3.2.2.48.(3),
which apply to floor assemblies entirely contained within dwelling
units in a building of residential
occupancy.
|
Top of Page | |
Intent | Intent 1: To limit the probability of the spread of fire from the
basement to an upper storey, which could lead to damage to the building.
Intent 2: To limit the probability of the premature collapse of the
floor assemblies in a fire situation, which could lead to damage to the building.
Intent 3: To direct Code users to Articles 3.2.2.20. to 3.2.2.83. for the determination of minimum fire-resistance
ratings for the floor assemblies. |