Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.1.4.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum fire-resistance rating of floor assemblies immediately above basements, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to a crawl space required to be considered as a basement, as stated in Sentence 3.2.2.9.(1).
Exceptions: 
except as exempted in Sentences 3.2.2.42.(3), 3.2.2.43.(3), 3.2.2.44.(3), 3.2.2.45.(3), 3.2.2.46.(3), 3.2.2.47.(3) and 3.2.2.48.(3), which apply to floor assemblies entirely contained within dwelling units in a building of residential occupancy.
Top of Page
Intent
Intent 1: 
To limit the probability of the spread of fire from the basement to an upper storey during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to harm to persons, including emergency responders.
Intent 2: 
To limit the probability of the premature collapse of the floor assemblies in a fire situation during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to harm to persons, including emergency responders.
Intent 3: 
To direct Code users to Articles 3.2.2.20. to 3.2.2.83. for the determination of minimum fire-resistance ratings for the floor assemblies.