Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.3.11.(1) | Application | Intent |
OP3 | OP3 |
Objective | OP3 Protection of Adjacent Buildings from Fire |
Attribution | |
Application | Application 1: Fire-resistance rating of
an exposing building face of noncombustible
construction of a building of low
hazard industrial occupancy conforming to Article 3.2.2.82.,
where the limiting distance is not less than 3
m. This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
|
Top of Page | |
Intent | Intent 1: To exempt certain exposing building faces from the requirements
of Sentences 3.2.3.1.(1) and 3.2.3.7.(1), (2) and (3), which would otherwise require a fire-resistance rating, on
the basis that the building has a low fire load, the exposing building face
is of noncombustible construction and the limiting distance is not less than 3
m. These conditions are to limit the probability of the spread of fire
from the building to an adjacent building, which could lead to damage to adjacent
buildings. |