Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.14.(1)
OS1OP1OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Minimum distance separating unprotected openings in two fire compartments, where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A where:
  • as stated in the latter part of Sentence 3.2.3.14.(3), unprotected openings of fire compartments are on opposite sides of a firewall, and
  • external walls of two buildings meet at a firewall at an angle of less than 135°, as stated in Sentence 3.1.10.6.(1), which also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability of the spread of fire from one fire compartment to a fire compartment in an adjacent building through unprotected openings in the exterior wall of the fire compartment of origin, which could lead to damage to adjacent buildings.