Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.14.(1)
OS1OP1OP3
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum distance separating unprotected openings in two fire compartments, where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies:
  • as stated in the latter part of Sentence 3.2.3.14.(3), to:
  • to external walls of two buildings that meet at a firewall at an angle of less than 135°, as stated in Sentence 3.1.10.6.(1), which also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.11.3.(1).
Exceptions: 
except as exempted in:
  • the first part of Sentence 3.2.3.14.(3), which applies to buildings that are sprinklered throughout,
  • Sentence 3.2.3.13.(1), which applies to the protection of openings in either the exterior wall of an exit or the exterior wall of a building under certain conditions, and
  • Sentence 3.2.3.19.(4), which applies to walkways of noncombustible construction used only as pedestrian thoroughfares.
Top of Page
Intent
Intent 1: 
To limit the probability of the spread of fire from one fire compartment to an adjacent fire compartment through unprotected openings in the exterior wall of the fire compartment of origin, which could lead to harm to persons in the adjacent fire compartment.
Top of Page