Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.1.9.(6)
OS3OS1
ObjectiveOS1 Fire Safety
Attribution
(b) [F05-OS1.5] [F06-OS1.5,OS1.2]
Application
Application 1: 
Maximum combined area of occupancies in a public corridor, where the public corridor conforms to Clause 3.4.2.5.(1)(d) [which requires the corridor to have a minimum width and ceiling height].
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To limit the probability of excessive fire loads in a public corridor, which could lead to the spread of fire in the corridor in a fire situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To limit the probability of excessive fire loads in a public corridor, which could lead to the spread of fire in the corridor in a fire situation, which could lead to ineffective fire emergency response operations, which could lead to:
  • delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons, and
  • the further spread of fire in the corridor, which could lead to harm to persons.