Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.4.2.5.(2) | Application | Intent |
+ | + |
Application | Application 1: Location of exits and maximum
travel distance to at least one exit, in a high
hazard industrial occupancy, where more than one exit is
required from a floor area. This
applies to floor areas, including mezzanines as
stated in Sentence 3.4.2.2.(1), in buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To exempt floor areas used for high-hazard industrial occupancies
from the permission in the latter part of Sentence 3.4.2.5.(2) to space
exits around the perimeter of a large building instead of the travel distance
limits of Sentence 3.4.2.5.(1), on the basis that the growth of a fire
will be so rapid that delays in evacuating are not acceptable, and the 25
m travel distance limit of Clause 3.4.2.5.(1)(a) is necessary.
|