Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.2.5.(2)
++
Application
Application 1: 
Location of exits and maximum travel distance to at least one exit, in a high hazard industrial occupancy, where more than one exit is required from a floor area.
This applies to floor areas, including mezzanines as stated in Sentence 3.4.2.2.(1), in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To exempt floor areas used for high-hazard industrial occupancies from the permission in the latter part of Sentence 3.4.2.5.(2) to space exits around the perimeter of a large building instead of the travel distance limits of Sentence 3.4.2.5.(1), on the basis that the growth of a fire will be so rapid that delays in evacuating are not acceptable, and the 25 m travel distance limit of Clause 3.4.2.5.(1)(a) is necessary.