Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.4.4.(6)
OS3OS1OP1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Use of exits for purposes other than for exiting.
This applies to exits serving floor areas that are intended for occupancy, including mezzanines as stated in Sentence 3.4.2.2.(1), in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that the use of exits other than for exiting will lead to exits being obstructed or not readily available in an emergency, which could lead to:
  • delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons, and
  • emergency responders being delayed in gaining access to floor areas, which could lead to emergency response operations being delayed or ineffective, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To limit the probability that the use of an exit other than for exiting could create a hazard in the exit, which could lead to harm to persons using the exit.
Intent 3: 
To waive the prohibition in the first part of Sentence 3.4.4.4.(6) on the use of exits for other purposes, and to allow access to floor areas, on the basis that this use:
  • does not create injury hazards or risks of obstructions in exits,
  • does not compromise the availability of the exits in an emergency, and
  • has the benefit of facilitating access of emergency responders to floor areas.