Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.8.3.7.(1)
OA2OS3
ObjectiveOA2 Barrier-Free Facilities
Attribution
[F74-OA2]
Application
Application 1: 
Assistive listening systems in seating areas of all classrooms, auditoria, meeting rooms and theatres with an area of more than 100 m2.
This applies to all buildings of assembly occupancy, as described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as stated in:
  • Sentence 3.8.3.7.(2), which applies to induction loop assistive listening systems, and
  • Sentence 3.8.1.1.(1), which applies to:
    • houses, including semi-detached houses, duplexes, triplexes, town houses, row houses and boarding houses,
    • buildings of Group F, Division 1 major occupancy, and
    • buildings that are not intended to be occupied on a daily or full-time basis, including automatic telephone exchanges, pumphouses and substations.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentences 9.5.2.1.(1) and 9.10.1.2.(2).
Exceptions: 
except as stated in Article 9.5.2.3., which applies to apartment buildings.
Top of Page
Intent
Intent 1: 
To limit the probability that a person with a hearing disability will be unable to properly hear performances or discussions in assembly occupancies and large classrooms, auditoria, meeting rooms and theatres.