Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.9.2.(1)
OS1+OP1
Application
Application 1: 
Combustibility of pipes, ducts, electrical outlet boxes, totally enclosed raceways or other similar service equipment that penetrate an assembly required to have a fire-resistance rating and that have been incorporated in the assembly at the time of testing, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except:
  • as stated in Article 3.1.9.3., which applies to certain wires and cables in noncombustible raceways or embedded in a concrete floor slab, certain cables of limited diameter, certain ungrouped cables, and combustible outlet boxes, and
  • as stated in Article 3.1.9.4., which applies to combustible sprinkler, water distribution, drain, waste and vent piping.
Top of Page
Intent
Intent 1: 
To exempt service equipment from the requirement to be noncombustible if certain testing has been conducted on the assemblies with the equipment installed, on the basis that the testing demonstrates that combustible service equipment will not reduce the structural integrity of the assembly in a fire condition.