Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.9.2.(1) | Application | Intent |
OS1 | + | OP1 |
Application | Application 1: Combustibility of pipes, ducts, electrical outlet
boxes, totally enclosed raceways or other similar service equipment that penetrate
an assembly required to have a fire-resistance rating and
that have been incorporated in the assembly at the time of testing, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions:
except:
|
Top of Page | |
Intent | Intent 1: To exempt service equipment from the requirement to be noncombustible
if certain testing has been conducted on the assemblies with the equipment
installed, on the basis that the testing demonstrates that combustible service
equipment will not reduce the structural integrity of the assembly in a fire
condition. |
Top of Page |