Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.1.(1)
OP1OS1OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Connections and supports for structural framing members that are connected to or supported on a firewall and have a fire-resistance rating less than that required for the firewall.
Exceptions: 
except as provided in Sentence 3.1.10.1.(2) where the firewall consists of two separate wall assemblies.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that the collapse of a structural framing member attached to or supported on the firewall will lead to failure of the firewall, which could lead to the spread of fire from the building to an adjacent building, which could lead to damage to the adjacent building.