Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.10.1.(1) | Application | Intent |
OP1 | OS1 | OP3 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Connections and supports for structural framing members
that are connected to or supported on a firewall and
have a fire-resistance rating less than that
required for the firewall.
Exceptions:
except as provided in Sentence 3.1.10.1.(2) where the firewall consists of two separate wall assemblies.
|
Top of Page | |
Intent | Intent 1: To limit the probability that the collapse of a structural
framing member attached to or supported on the firewall will lead to failure
of the firewall, which could lead to the spread of fire from an adjacent building
to the building, which could lead to damage to the building. |