Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.8.(1)
OS1OP1OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Protection of the exterior surface of foamed plastic insulation used in exterior walls of buildings described in Sentence 1.3.3.2.(1) of Division A that:
Exceptions: 
except as exempted in Sentence 3.2.3.8.(3), which applies to wall assemblies that comply with the requirements of Article 3.1.5.5.
Application 2: 
This also applies to exterior walls enclosing an attic or roof space located above an exposing building face, as stated in Sentence 3.2.3.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that, in the event of a fire, the foamed plastic insulation will be ignited, which could lead to the involvement of the foamed plastic insulation, which could lead to increased radiation to an exposed adjacent building, which could lead to the spread of fire to the adjacent building during the time required for emergency responders to perform their duties, which could lead to damage to the adjacent building.