Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.8.3.11.(1) | Application | Intent |
OA2 | OH2 | OS3 |
Objective | OA2 Barrier-Free Facilities |
Attribution | |
Application | Application 1: Lavatories, in washrooms required by Article 3.8.2.3. to
be barrier-free [washrooms in a storey to
which a barrier-free path of travel is required
in accordance with Article 3.8.2.1.]. Application 2: This also applies to lavatories in universal toilet
rooms provided primarily for the use of persons of both sexes with physical
disabilities, in lieu of facilities for persons with physical disabilities
in washrooms used by the general public, in existing buildings where alterations are being made, as stated in Sentence 3.8.2.3.(4) and Clause 3.8.3.12.(1)(c). This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To limit the probability that a person using a manual wheelchair
or other manual mobility assistance device will not be able to use a lavatory
in a barrier-free washroom without the assistance of another person.
Intent 2: [Subclause (c)(i)] To exempt lavatories from the requirement
for a greater minimum width as stated in Sentence 3.8.1.3.(1) and permit
a lesser minimum width, on the basis that lavatories need not be wider to
allow proper usage by persons using manual wheelchairs or other manual mobility
assistance devices. |
Top of Page |