Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.3.3.(2)
++
Application
Application 1: 
Side of exposure to fire for the fire-resistance rating of exterior walls of buildings.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except that the exterior walls need not comply with the temperature rise limitations required by the standard tests referred to in Article 9.10.3.1. if:
  • such walls have a limiting distance of not less than 1.2 m, and
  • due allowance is made for the effects of heat radiation in accordance with the requirements in Part 3.
Top of Page
Intent
Intent 1: 
To clarify that the fire-resistance rating for exterior wall assemblies is determined by exposing the assemblies to fire from inside the building, which is expected to represent the most severe exposure condition.
Top of Page