Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.11.2.(3)
OS1OP3
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Fire stopping of any spaces between the top of the wall described in Sentence 9.10.11.2.(1) [a party walls on a property line between dwelling units, where the wall is constructed as a fire separation having not less than a 1 h fire-resistance rating ] and the roof deck.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are of residential occupancy and in which there is no dwelling unit above another dwelling unit.
Top of Page
Intent
Intent 1: 
To limit the probability that fire will spread through spaces between the top of a party wall and a roof deck, which could lead to the spread of fire into the roof deck from one building to another, which could lead to harm to persons in the building not originally involved in the fire.
Top of Page