Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.18.3.(3)
+OS1
Application
Application 1: 
Heat detectors and smoke detectors described in Sentence 9.10.18.3.(2) [heat detectors or smoke detectors in storage rooms, service rooms, elevator shafts, chutes, janitors' closets and any other rooms where hazardous substances are intended to be used or stored], in dwelling units.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] where fire alarm systems are required [see Article 9.10.18.2.].
Top of Page
Intent
Intent 1: 
To exempt dwelling units from the requirements of Sentence 9.10.18.3.(2), which would otherwise require heat or smoke detectors in certain spaces, on the basis that dwelling units are provided with smoke alarms, as required in Subsection 9.10.18.