Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.20.1.(1) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Minimum opening size, and maximum sill height above
floor level, of window or access panels [for firefighting] on the second and
third storeys of buildings in
at least one wall facing on a street, where such storeys are not sprinklered.
This applies to buildings to which Part
9 applies [see Sentence 1.3.3.3.(1) of Division A for application of
Part 9].
Exceptions:
except as stated in Sentence 9.10.20.1.(3), which applies to buildings containing only dwelling
units where there is no dwelling unit above
another dwelling unit.
|
Top of Page | |
Intent | Intent 1: To limit the probability of delays or ineffectiveness in
fire emergency response operations, which could lead to the spread of fire
to other parts of the building, which could lead to damage to the building.
|
Top of Page |