Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.20.1.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum opening size, and maximum sill height above floor level, of window or access panels [for firefighting] on the second and third storeys of buildings in at least one wall facing on a street, where such storeys are not sprinklered.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.10.20.1.(3), which applies to buildings containing only dwelling units where there is no dwelling unit above another dwelling unit.
Top of Page
Intent
Intent 1: 
To limit the probability of delays or ineffectiveness in fire emergency response operations, which could lead to:
  • delays in the evacuation or movement of persons to a safe place, and
  • the spread of fire to other parts of the building.
This is to limit the probability of harm to persons.