Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.21.3.(1) | Application | Intent |
OS1 | + | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of fire separations that separate floor assemblies separating
the first storey and the second storey in
construction camp buildings. This
applies to construction camps to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions:
except in dwelling units.
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentences 9.10.8.1.(1) and 9.10.21.1.(1), which would otherwise
require a minimum 45 min fire-resistance rating, and permit a
lower minimum fire-resistance rating, on the basis that this rating is considered
adequate for construction camps. Intent 2: To limit the probability of fire on one storey of a construction
camp spreading to another storey during the time required for occupants to
leave the space, which could lead to harm to persons on the other storey.
|
Top of Page |