Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.18.2.1.(2)
OH1OS2OH2
ObjectiveOS2 Structural Safety
Attribution
[F63-OS2.3] Applies where crawl spaces are unheated and access is from the interior.
[F42,F61-OS2.3] Applies where crawl spaces are heated or unheated and access is from the exterior.
Application
Application 1: 
Closures for access openings for crawl spaces whose exterior walls have less than 25% of their total area above exterior ground level open to the outdoors, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except for heated crawl spaces that are accessible from the interior.
Top of Page
Intent
Intent 1: 
To limit the probability of unprotected access openings, which could lead to:
  • where crawl spaces are unheated and access is from the interior, moisture transfer from the interior, or
  • where crawl spaces are heated or unheated and access is from the exterior:
    • the ingress of precipitation, or
    • an infestation of insects or vermin.
This is to limit the probability of compromised structural integrity, which could lead to:
  • structural failure, or
  • for environmental separators or elements supporting an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements.
This is to limit the probability of harm to persons.