Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.18.2.1.(2)
OH1OS2OH2
ObjectiveOH1 Indoor Conditions
Attribution
[F51,F63-OS2.3] Applies where crawl spaces are unheated and access is from the interior.
[F42,F61-OS2.3] Applies where crawl spaces are heated or unheated and access is from the exterior.
Application
Application 1: 
Closures for access openings for crawl spaces whose exterior walls have less than 25% of their total area above exterior ground level open to the outdoors, where:
  • crawl spaces are unheated and access is from the exterior,
  • crawl spaces are unheated and access is from the interior, or
  • crawl spaces are heated and access is from the exterior.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except for heated crawl spaces that are accessible from the interior.
Top of Page
Intent
Intent 1: 
To limit the probability of unprotected access openings, which could lead to:
  • where crawl spaces are unheated and access is from the interior, moisture transfer from the interior, or
  • where crawl spaces are heated or unheated and access is from the exterior:
    • the ingress of precipitation,
    • an infestation of insects or vermin, or
    • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of the temperature of interior spaces, relative humidity or drafts,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of environmental separators or of elements protected by the separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.