Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.2.4.(1)
OS2OP2OH1OH4OS3OP1OS1
ObjectiveOS1 Fire Safety
Attribution
[F80-OS1.2] Applies to masonry used in chimneys and fireplaces.
Application
Application 1: 
Above-ground unreinforced masonry, nominally reinforced masonry where vertical joints in adjacent courses are aligned [see Article 9.20.9.1.], loadbearing masonry of buildings of more than one storey in regions where the spectral response acceleration Sa(0.2) is greater than 0.55 that are reinforced in accordance with Sentence 9.20.1.2.(1), and loadbearing masonry of 3-storey buildings in regions where the spectral response acceleration Sa(0.2) is greater than 0.35 and less than or equal to 0.55 that are reinforced in accordance with Sentence 9.20.1.2.(2), made with cellular (foamed) concrete blocks, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height above the foundation wall does not exceed 11 m, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to sulfate attack or stresses resulting from water absorption and freeze-thaw cycling.
For chimneys and fireplaces, this is to limit the probability of excessive heat transfer, which could lead to the ignition of combustible building components, which could lead to harm to persons.