This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.20.12.2.(2) | Application | Intent |
OH1 | OS2 | OP2 | OH4 | OS3 |
Objective | OH4 Vibration and Deflection Limitation |
Attribution | |
Application | Application 1: In buildings to which Part
9 applies [see Sentence 1.3.3.3.(1) of Division A for application of
Part 9], corbeling of unit-masonry foundation walls
supporting above-ground, unreinforced masonry cavity
walls that are thicker than the foundation wall
on which they rest:
Exceptions:
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry
is designed for specified loads on the basis of ultimate and serviceability
limit states.
|
Top of Page | |
Intent | Intent 1: To limit the probability that the cavity wall's centre of
gravity will be too far outboard of its supporting foundation, which could
lead to excessive eccentricity of loads, which could lead to cracking of cavity
walls. This is to limit the probability of:
For floors and elements supporting floors, this is to limit the
probability of excessive movement, deflection or vibration, which could lead
to negative effects on the psychological well-being of persons.
|
Top of Page |