Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.13.1.(1)
OS2OP2OH1OS1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Materials used for, and minimum thicknesses of, flashing of masonry, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height above the foundation wall does not exceed 11 m, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of using inappropriate flashing materials or installing an inadequate thickness of flashing, which could lead to premature failure of flashing upon exposure to moisture, sunlight, temperature extremes or mechanical stresses.
This is to limit the probability of:
  • precipitation or meltwater ingress, or
  • compromised thermal performance of components intended to resist heat transfer.
This is to limit the probability of:
  • an inadequate control of temperatures in interior spaces, relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.
Top of Page