Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.21.4.9.(2) | Application | Intent |
OS2 | OH1 | OS3 | OS1 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Prevention of the lateral displacement of flue liners
in the same rectangular chimney of brick masonry
or concrete, which is not more than 12 m in height and serves
fireplaces or appliances having a combined total
rated heat output of 120 kW or less, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. Application 2: This also applies to rectangular masonry
or concrete chimneys, in buildings to which
Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application
of Part 6], as stated in Sentence 6.3.1.2.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability that joints between flue liner
sections will open, which could lead to the spillage of combustion products,
which could lead to the leakage of carbon monoxide gas into living space,
which could lead to the acute poisoning or asphyxiation of persons.
|
Top of Page |