Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.3.4.(2)
OS2OP2OH1OS1OH4OS3
ObjectiveOS3 Safety in Use
Attribution
[F22-OS3.1] Applies to floors and elements that support floors.
[F22-OS3.7] Applies to walls, and elements that support walls, that contain doors or windows required for emergency egress.
Application
Application 1: 
Fastening of lumber exterior-wall framing to lumber floor framing, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.], where the sole plate is not fastened to the floor joists or blocking with nails at least 82 mm long spaced not more than 400 mm o.c.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate fastening or an excessive rate of deterioration of fasteners, which could lead to an inability to resist expected wind loads, which could lead to the separation of exterior walls or wall elements from floors, which could lead to overturning, lifting or sliding of exterior walls.
This is to limit the probability of:
  • compromised structural integrity,
  • where elements support or are part of an environmental separator, the failure of required environmental separation elements, which could lead to deterioration, or
  • an inability to resist expected loads, which could lead to:
    • the excessive deflection or vibration of floors, or
    • the excessive movement or deformation of walls.
This is to limit the probability of:
  • compromised operation of doors or windows required for egress in an emergency, and
  • persons losing their balance, tripping or falling.
This is to limit the probability of harm to persons.
Intent 2: 
To exempt situations from the application of Sentence 9.23.3.4.(1) where another means of fastening the wall framing to the floor framing is provided.