Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.3.5.(4)
OS2OP2OH4OS3OS1
ObjectiveOS3 Safety in Use
Attribution
[F22-OS3.1] Applies to floors and elements that support floors.
Application
Application 1: 
Minimum diameter of flooring screws used to fasten subflooring to the framing members, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate diameter of screws, which could lead to inadequate capacity or rigidity, which could lead to an inability to resist expected dead and live gravity loads, which could lead to fastened elements detaching from supporting members, which could lead to excessive movement, deformation or deflection.
For floors and elements supporting floors, this is to limit the probability:
  • compromised structural integrity, or
  • where members support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to deterioration.
This is to limit the probability of excessive deflection or vibration of floors, which could lead to persons losing their balance, tripping or falling, which could lead to harm to persons.