Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.3.5.(4)
OS2OP2OH4OS3OS1
ObjectiveOS1 Fire Safety
Attribution
[F20-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Minimum diameter of flooring screws used to fasten subflooring to the framing members, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate diameter of screws, which could lead to inadequate capacity or rigidity, which could lead to an inability to resist expected dead and live gravity loads, which could lead to fastened elements detaching from supporting members, which could lead to excessive movement, deformation or deflection.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.