Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.13.7.(1)
OS2OP2OH1OS1
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Collar ties or ceiling joists providing intermediate support for roof rafters or joists, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.], where the roof slope is 1 in 3 or greater.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate strength of intermediate support for rafters, which could lead to an inability to resist expected compressive loads transferred from opposing rafters, which could lead to failure of intermediate support members.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.
Intent 2: 
To further define the application of the span tables.