Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.23.13.7.(1) | Application | Intent |
OS2 | OP2 | OH1 | OS1 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Collar ties or ceiling joists providing intermediate
support for roof rafters or joists, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application
of Section 9.23.], where the roof slope is 1 in 3 or greater.
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate strength of intermediate
support for rafters, which could lead to an inability to resist expected compressive
loads transferred from opposing rafters, which could lead to failure of intermediate
support members. This is to limit the probability of
compromised structural integrity, which could lead to:
This is to limit the probability of harm to persons
Intent 2: To further define the application of the span tables.
|
Top of Page |