Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.25.3.2.(1)
OH1OS2OS1OS3
ObjectiveOS3 Safety in Use
Attribution
[F20,F44-OS3.4] Applies where the air barrier system separates a garage, or suite containing a garage, from residential space.
Application
Application 1: 
Characteristics of required air barrier systems, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to air pressure loads, which could lead to:
  • the air barrier rupturing, tearing or puncturing at fasteners, or
  • the opening of joints in the air barrier.
Where the air barrier system separates a garage, or suite containing a garage, from residential space, this is to limit the probability of a loss of airtightness, which could lead to the leakage of carbon monoxide gas into living space, which could lead to the asphyxiation or acute poisoning of persons.