Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.26.11.8.(1)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Installation of built-up roofing applied over wood, plywood, OSB or waferboard roof sheathing, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.26.11.8.(2), which applies where joints of plywood, OSB or waferboard are taped and the sheathing is primed with asphalt.
Top of Page
Intent
Intent 1: 
To limit the probability of the absorption of bitumen by porous roof sheathing or the draining of bitumen through gaps between sheets of roof sheathing, which could lead to an insufficient thickness of bitumen to achieve the required degree of watertightness and adhesion of the roofing membrane, which could lead to water penetrating directly to roof decking or sheathing, which could lead to deterioration, which could lead to the structural failure of roofs or elements protected by roofs, which could lead to harm to persons.