Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.26.11.8.(1) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Installation of built-up roofing applied over wood,
plywood, OSB or waferboard roof sheathing, on buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except as stated in Sentence 9.26.11.8.(2), which applies where
joints of plywood, OSB or waferboard are taped and the sheathing is primed
with asphalt.
|
Top of Page | |
Intent | Intent 1: To limit the probability of the absorption of bitumen by
porous roof sheathing or the draining of bitumen through gaps between sheets
of roof sheathing, which could lead to an insufficient thickness of bitumen
to achieve the required degree of watertightness and adhesion of the roofing
membrane, which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|