Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.28.3.2.(1)
OH1OS2OS1OS3OP1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Minimum shank and head diameter of nails for stucco lath and reinforcing, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of the shear failure or withdrawal of nails, which could lead to inadequate support for stucco lath or reinforcing, which could lead to delamination or cracking under gravity, wind or impact loads, or freeze-thaw stresses.
This is to limit the probability of:
  • precipitation or meltwater ingress, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of temperatures of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of exterior walls or elements protected by exterior walls.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.