Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.28.6.3.(2)
OH1OS2OS1OS3OP1
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Scoring of the first coat of stucco, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate physical bond between the first and second coats of stucco, which could lead to stucco being of inadequate strength to resist gravity, lateral or impact loads, which could lead to delamination.
This is to limit the probability of:
  • precipitation or meltwater ingress, which could lead to deterioration, which could lead to the structural failure of exterior walls or elements protected by exterior walls, or
  • stucco detaching and falling from the building.
This is to limit the probability of harm to persons.
Top of Page