Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.28.6.3.(2) | Application | Intent |
OH1 | OS2 | OS1 | OS3 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Scoring of the first coat of stucco, on buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of an inadequate physical bond
between the first and second coats of stucco, which could lead to stucco being
of inadequate strength to resist gravity, lateral or impact loads, which could
lead to delamination. Where stucco is applied to masonry
chimneys, this is to limit the probability of precipitation or meltwater ingress,
which could lead to the premature failure of chimney liners, which could lead
to the escape of heat or flames, which could lead to the ignition of combustible
building components, which could lead to harm to persons.
|