Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.6.4.(8)
OH1OS1OP1OS2
ObjectiveOP1 Fire Protection of the Building
Attribution
[F03-OP1.1] Applies to air duct distribution systems.
Application
Application 1: 
Installation of linings of ducts near fire dampers, fire stop flaps and other closures, in air duct distribution systems serving heating systems in which the rated heat input does not exceed 120 kW and serving only one dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to ventilation ducts and their fittings, as stated in Sentence 9.32.3.11.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that duct lining will interfere with the opening or closing of fire dampers, which could lead to an inability to retard the spread of fire and smoke to other parts of the building, which could lead to damage to the building.