Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.6.4.(8)
OH1OS1OP1OS2
ObjectiveOS2 Structural Safety
Attribution
[F63-OS2.3] Applies to air duct distribution systems.
Application
Application 1: 
Installation of linings of ducts near volume or balancing dampers, in air duct distribution systems serving heating systems in which the rated heat input does not exceed 120 kW and serving only one dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to ventilation ducts and their fittings, as stated in Sentence 9.32.3.11.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that duct lining will interfere with the opening or closing of dampers, which could lead to an inability to balance the flow of intake and exhaust air, which could lead to an inability to maintain adequate indoor air temperatures, which could lead to condensation, which could lead to deterioration, which could lead to compromised structural integrity, which could lead to harm to persons.