Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.2.2.2.(2)
OS2OH1OH4
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Calculation of wind load for the design of materials, components, assemblies and their connections, where these are:
  • subject to wind load, and
  • required to be designed to resist wind load.
This applies to building materials, components, assemblies and their interfaces described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Application 2: 
This also applies to cladding assemblies installed on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] where:
  • the cladding assembly is not addressed in Section 9.27., or
  • the cladding assembly does not comply with the prescriptive requirements of Section 9.27.
Exceptions: 
except as stated in:
  • Sentence 5.4.1.1.(3), which applies to air barrier systems where a lack of resistance to air leakage will not negatively affect health, safety, the intended use of the building or the operation of building services, and
  • Sentence 5.2.2.2.(3), which applies where it can be shown that the material, component, assembly or connection in question is subject to less that 100% of the wind load.
Top of Page
Intent
Intent 1: 
To limit the probability of using inappropriate wind load assumptions, which could lead to the deflection, movement and deterioration of required environmental separation elements subject to wind load, which could lead to the failure of such elements, which could lead to the inadequate control of:
  • precipitation ingress due to air pressure differences,
  • condensation, or
  • the ingress of airborne moisture from the ground.
This is to limit the probability of compromised structural integrity of the separators or of elements protected by the separators, which could lead to structural failure, which could lead to harm to persons.
Intent 2: 
To expand the application of Subsection 4.1.7. to wind loads on elements identified in Sentences 5.1.4.1.(3) and 5.2.2.2.(1), with respect to the direct implications of non-compliance with the objectives of Structural Safety and Structural Sufficiency of the Building.