Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.2.9.(3)
OS2OP2OH1OH4OS3OS1
ObjectiveOS1 Fire Safety
Attribution
[F80-OS1.2] Applies where structural wood elements support or are used in assemblies that are required to provide fire resistance.
Application
Application 1: 
Pressure treatment of structural wood elements with a preservative, where the structural wood elements are:
  • less than 150 mm above ground, or
  • not protected from exposure to precipitation, where the configuration is conducive to moisture accumulation and the moisture index is greater that 1.0.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of wood decay.
Where structural wood elements support or are used in assemblies that are required to provide fire resistance, this is to limit the probability of the compromised fire resistance of the assembly, which could lead to harm to persons.