Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.7.2.1.(1)
OH1OS2OS1
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Windows, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that the performance of windows will fall significantly below expectations with respect to:
  • strength,
  • deflection,
  • resistance to condensation, and
  • precipitation ingress and dissipation.
This is to limit the probability of:
  • compromised structural integrity of window assemblies and adjacent exterior wall assemblies, or
  • precipitation ingress or condensation, which could lead to deterioration, which could lead to compromised structural integrity of window assemblies and adjacent exterior wall assemblies.
This is to limit the probability of harm to persons.
Top of Page