Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.21.2.1.(3)
OS3OH1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Chimney flues serving solid-fuel-burning appliances having a combined total rated heat output of 120 kW or less, where rectangular masonry or concrete chimneys are not more than 12 m in height, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to chimney flues serving solid-fuel-burning appliances having a combined total rated heat output of 120 kW or less, where rectangular masonry or concrete chimneys are not more than 12 m in height, in buildings to which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6], as stated in Sentence 6.3.1.2.(1).
Exceptions: 
except for the installation of appliances where an adequate draft is maintained for each appliance and the installation of both appliances meets the requirements of the relevant standards referenced in Article 9.33.5.2.
Top of Page
Intent
Intent 1: 
To limit the probability that combustion products will spill from one or more appliances into living space, which could lead to the acute poisoning or asphyxiation of persons.