Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.1.(1)
OS3OH1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Heating-season mechanical ventilation systems serving single dwelling units that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Top of Page
Intent
Intent 1: 
To limit the probability of the inadequate replacement of indoor air with outdoor air, which could lead to excessive negative pressure in dwelling units, which could lead to the spillage of combustion products from fuel-burning appliances that are susceptible to spillage.
This is to limit the probability of the entry of carbon monoxide gas into living space, which could lead to the acute poisoning or asphyxiation of persons.
Top of Page