Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.5.2.(1)
OP1OH1OS2OS3OS1
ObjectiveOP1 Fire Protection of the Building
Attribution
[F01-OP1.1] Applies to heating equipment.
Application
Application 1: 
Installation of heating equipment, including provisions for mounting, clearances and air supply, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in:
  • Article 9.33.5.3., which applies to solid-fuel-burning stoves, ranges and space heaters, and
  • Article 9.33.5.4., which applies to fireplaces.
Top of Page
Intent
Intent 1: 
To limit the probability that the installation of heating equipment will fall significantly below expectations, which could lead to:
  • the inadequate performance or failure of components,
  • fuel or gas leaks, or
  • overheating of components.
This is to limit the probability of a fire or explosion, which could lead to damage to the building.