Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
2.4.9.5.(2) | Application | Intent |
OH2 |
Objective | OH2 Sanitation |
Attribution | |
Application | Application 1: Leaders with a nominally
horizontal offset more than 6 m long
that drain to storm building drains, storm
building sewers or combined building sewers,
in drainage systems for buildings.
|
Top of Page | |
Intent | Intent 1: To supersede the requirement stated in Sentence 2.4.9.5.(1) regarding
leaders. This is to limit the probability that hydraulic
load drained to inappropriately sized leaders will lead to a backup or overflow,
which could lead to unsanitary conditions, which could lead to harm to persons.
|
Top of Page |