Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
2.5.4.3.(2) | Application | Intent |
| OH1 |
| Objective | OH1 Indoor Conditions |
| Attribution | |
| Application | Application 1: Connection of yoke vents to soil-or-waste stacks that receive discharge from fixtures located on more than 11 storeys,
in plumbing systems for buildings.
|
| Top of Page | |
| Intent | Intent 1: To limit the probability that the connection of yoke vents
by means of an inappropriate fitting or at an inappropriate location will
lead to the accumulation of sewage in yoke vents, which could lead to a reduced
vent capacity, which could lead to siphonic action or back pressure in drainage
systems, which could lead to trap seal failure, which could lead to the entry
of sewer gases into occupied space, which could lead to negative effects on
indoor air quality, which could lead to harm to persons. |