Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

2.2.3.1.(2)
OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Minimum trap seal depth on fixtures draining to acid waste systems, in buildings.
Top of Page
Intent
Intent 1: 
To modify the requirements of Sentence 2.2.3.1.(1) [specifically Clause 2.2.3.1.(1)(a)], which would otherwise permit a lesser depth, on the basis that a greater minimum trap seal depth will provide additional protection where exposure to acid gases is possible in an acid waste system. This [greater seal depth] is to limit the probability that inertia of the water flow [pressure differential] and evaporation, or malfunction of mechanical devices, will lead to the failure of trap seals, which could lead to the leakage of sewer gases into the building, which could lead to a negative effect on indoor air quality, which could lead to harm to persons.