Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
2.4.9.3.(2) | Application | Intent |
| OH2 |
| Objective | OH2 Sanitation |
| Attribution | |
| Application | Application 1: Minimum size for fixture
outlet pipe that is common to 3 compartments of a sink, in drainage
systems for buildings. |
| Top of Page | |
| Intent | Intent 1: To supersede the requirement in Sentence 2.4.9.3.(1) for
minimum fixture outlet pipe size, where fixture outlets serve multiple compartments
of the same sink that might be drained simultaneously and for which the hydraulic
load is likely to be higher, but not likely to be as high as would be imposed
by separate sinks. This is to limit the probability that
inadequate size will lead to an inability to drain multiple sink compartments
simultaneously, which could lead to a backup, which could lead to unsanitary
conditions, which could lead to harm to persons.
|